Model |
LY1-D | |||
| Technical Parameters | ||||
| Rate Operating Voltage Uc(V~) | 220V | 380V | 220V | 380V |
| Maximum Continuous Operating Voltage Uc(V~) | 275V | 385V | 320V | 385V |
| Voltage Protection Level Up(V~)kA | ≤0.7 | ≤1.0 | ≤1.2 | ≤1.5 |
| Nominal Discharge Current In(8/μ20μs)kA | 5 | 10 | ||
| Maximum Discharge Current Imax(8/μ20μs)kA | 10 | 20 | ||
| Response Time ns | <25 | |||
| Test Standard | GB18802.1\IEC61643-1 | |||
| L/N(mm2)The Cross Section of L/N Line | 6 | |||
| PE(mm2)The Cross Section of PE Line | 16 | |||
| Fuse or Switch(A) | 10A,16A | 16A,25A | ||
| Operating Environment°C | -40°C~+85°C | |||
| Relative Humidity(25°C) | ≤95% | |||
| Installation | Standard Rail 35mm | |||
| Material Of Outer Covering |
Fiber glass reinforced plastic
|
|||
| Technical parameters | LY1-C | N-PE | |||||||||||
| Rated operating voltage Un | 110V | 220V | 380V | 220V | 380V | 220V | 380V | ||||||
| Max continuous operating voltage Uc | 140V | 275V | 320V | 385V | 420V | 440V | 275V | 320V | 385V | 420V | 440V | 255V | |
| Voltage protection level Up | <=0.8 | <=1.2 | <=1.5 | <=1.8 | <=2.0 | <=1.2 | <=1.0 | <=1.4 | <=1.5 | <=1.8 | <=2.0 | <=1.0/<=1.0/<=1.8 | |
| Normal discharge current In | 20kA | 15kA | 5kA/12.5kA/25kA | ||||||||||
| Max discharge current Imax | 40kA | 30kA | |||||||||||
| Response time | <25ns | 100ns | |||||||||||
| Test standard | GB18802,IEC61643-1 | ||||||||||||
| The cross section of L/N line | 10,16mm 2 | 10mm2 | |||||||||||
| The cross section of PE line | 10,25mm 2 | 16mm2 | |||||||||||
| Fuse or Switch | 32A | 25A,32A | |||||||||||
| Operating environment | -40~+85 degrees | ||||||||||||
| Relative humidity | <=95% | ||||||||||||
| Installation | Standard rail 35mm | ||||||||||||
| Material of outer covering | Fiber glass reinforced plastic | ||||||||||||
| Technical parameters | LY1-B | |||||
| Rated operating voltage Un | 220V | 380V | 220V | 380V | 220V | 380V |
| Max continuous operating voltage Uc | 385V | 420V | 385V | 420V | 385V | 420V |
| Voltage protection level Up | <=2.8 | <=3.2 | <=2.2 | <=2.5 | <=2.0 | <=2.3 |
| Normal discharge current In | 60kA | 40kA | 30kA | |||
| Max discharge current Imax | 100kA | 80kA | 60kA | |||
| Response time | <25ns | |||||
| Test standard | GB18802,IEC61643-1 | |||||
| The cross section of L/N line | 16,25mm 2 | 10,16mm 2 | 10,16mm 2 | |||
| The cross section of PE line | 25,35mm 2 | 25mm 2 | 16,25mm 2 | |||
| Fuse or Switch | 63,100A | 63A | 32,63A | |||
| Operating environment | -40~+85 degrees | |||||
| Relative humidity | <=95% | |||||
| Installation | Standard rail 35mm | |||||
| Material of outer covering | Fiber glass reinforced plastic | |||||