Panelroof Single Phase 8kw Grid- Tied Solar Power Lnverter for Lithium Battery

Model NO.
LS Inverter/Solar Inverter
Brand
Panekroof
Type
DC/AC Inverters
Power Source
Solar Power
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Sine Wave Inverter
Charging Mode
MPPT Solar Inverter
Output Frequency
45/65Hz Solar Inverter
Protection
Overload/Short Circuit/Temperature Protection
Battery Type
Lithium /Lead Acid /Gel Battery and Others
Rated Output Voltage (VAC)
110V/120V/220V/230V/240V
Size
500X300X140mm~530X355X150mm
Application
Application
Transfer Time
>4ms
N.W (Kg)
13.3kg~26kg
Color
Blue Solar Inverter /OEM/ODM
Charging Current
10A~60A
Product Name
Home Solar Inverter for Home Use
Communication
RS485/APP(WiFi Monitoring or GPRS Monitoring)
Display
LCD Display
Model No.
Ls
Transport Package
Wooden Box
Specification
Customized
Trademark
Panelroof
Origin
Xiamen
HS Code
8504403090
Production Capacity
50000 Pieces/Year
Reference Price
$ 180.00 - 360.00

Product Description

Product Description

Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery

 
LS Inverter/Solar Inverter


1.Rated Power;1000W-6000W;
2.Peak Power(20ms);3000VA-18000VA.
3.Start Motor;1HP-4HP.
4.Low frequencytoroidal transformer lower loss.
5.Built-in PWM or MPPTcontroller optional.
6.Intelligent LCD integration display.
Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery
 
Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery
     Application Area



1,Office and public facilities, household system, network transmission equipment, manufacturing, control system, solar energy system, oilfield, drilling field operation, etc.
2,Provide stable, reliable and safe solutions for families, islands, shipsand other small photovoltaic power systems.

 

Specification
Model LS/LS-T10212/24/48
(102)
15212/24/48
(152)
20232/24/48
(202)
30224/48
(302)
40224/48
(402)
50248
(502)
60248
(602)
Rated Power1000W1500W2000W3000W4000W5000W6000W
Peak Power(20ms)3000VA4500VA6000VA9000VA12000VA15000VA18000VA
Start Motor1HP1.5HP2HP3HP3HP4HP4HP
Battery Voltage12/24/48VDC24/48VDC24/48VDC48VDC
Size(L*W*Hmm)500*300*140530*335*150
Packing Size(L*W*Hmm)565*395*225605*430*235
N.W.(kg)1213.51820222426
G.W.(kg)(Carton Packing)13.51519.521.5242628
Installation MethodWall-Mounted
Parameter
InputDC Input Voltage Range10.5-15VDC(Single battery voltage)
AC Input Voltage Range85VAC~138VAC(110VAC) / 95VAC~148VAC(120VAC) / 170VAC~275VAC(220VAC) / 180VAC~285VAC(230VAC) / 190VAC~295VAC(240VAC)
AC Input Frequency Range45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current0~30A(Depends on model)
AC charging methodThree-stage (constant current, constant voltage, floating charge)
OutputEfficiency(Battery Mode)≥85%
Output Voltage(Battery Mode)110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode)50/60Hz±1%
Output Wave(Battery Mode)Pure Sine Wave
Efficiency(AC Mode)>99%
Output Voltage(AC Mode)110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Output Frequency(AC Mode)Follow input
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode)≤0.8% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Battery TypeVRLA BatteryCharge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customize batteryCharging and discharging parameters of different types of batteries can be customized according to user requirements
 (charging and discharging parameters of different types of batteries can be set through the operation panel)
ProtectionBattery undervoltage alarmFactory default: 11V(Single battery voltage)
Battery undervoltage protectionFactory default: 10.5V(Single battery voltage)
Battery overvoltage alarmFactory default: 15V(Single battery voltage)
Battery overvoltage protectionFactory default: 17V(Single battery voltage)
Battery overvoltage recovery voltageFactory default: 14.5V(Single battery voltage)
Overload power protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection>90°C(Shut down output)
AlarmANormal working condition, buzzer has no alarm sound
BBuzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
CWhen the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging ModeMPPT or PWM
Charging current10A~60A(PWM or MPPT)10A~60A(PWM )  / 10A~100A(MPPT)
PV Input Voltage RangePWM: 15V-44V(12V System); 30V-44V(24V System); 60V-88V(48V System)
MPPT: 15V-120V(12V System); 30V-120V(24V System); 60V-120V(48V System)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM: 50V(12V/24V System ); 100V(48V System)  /  MPPT: 150V
PV Array Maximum Power12V System: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A);
24V System: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A;
48V System: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)
Standby loss≤3W
Maximum conversion efficiency>95%
Working ModeBattery First/AC First/Saving Energy Mode
Transfer Time≤4ms
DisplayLCD
Thermal methodCooling fan in intelligent control
CommunicationRS485/APP(WIFI monitoring or GPRS monitoring)
EnvironmentOperating temperature≤55dB
Storage temperature-10ºC~40ºC
Noise-15ºC~60ºC
Elevation2000m(More than derating)
Humidity0%~95% ,No condensation
 

Factory Shop

Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery

Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery

Installation Instructions

Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery

Packaging & Shipping

Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery
Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery

Company Profile

Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery

                             Xiamen Panelroof PV Technology Co.,Ltd.
     Xiamen Panelroof PV Technology Co., Ltd was established in Xiamen, the beautiful coastal city in south China. In order to provide best products and services, Xiamen Panelroof has invested a lot of capital in R&D to improve the skills and technologies of manufacturing and system design. Our R&D team are all senior experts in the photovoltaic industry, now Xiamen Panelroof had become a comprehensive high-tech enterprise specializes in solar system design, solar panel, solar bracket, solar inverter, energy storage battery manufacturing and sales. High quality and good services had earned us a high reputation from our customers and partners. We will keep searching and innovating and improving our design, products quality and customer service to expand our influence all over the world.

Certifications

Panelroof Single Phase 8kw Grid-Tied Solar Power Lnverter for Lithium Battery

FAQ

Q1: What is the rated power do I need for my house?
A2: Please contact our sales, we will give you suggestions as per the electrical appliances you have in your house.
Q2: Do you have installation instructions for the solar power system?
A2: Yes,for all solar power systems order, we will make an installation guide along with the goods.
Q3: Which kind of solar system do I need? On grid or off grid type?
A3: If you want to sell the electricity generated by the solar,you need to use on grid system.If you only want to use the solar energy to the electrical appliances in your house,you need off grid system.
Q4: What is the lead time of your solar power system?
A4: Around 25 days.
Q5:What is the warranty of your solar power system?
A5:10 years for solar panels, 3 years for inverters and 1 year for batteries.
Q6: Can we install the system on the sloping roof?
A6: Yes,our system can be installed on both sloping roof and flat roof.






 

 