| ITEM | Model | N-SUB1500 | N-SUB3000 | N-SUB3500 | N-SUB5000 | N-SUB5500 | N-SUB5000P |
| INPUT | RATED POWER | 1.5KW | 3KW | 3.5KW | 5KW | 5.5KW | 5KW |
| Voltage | 230 VAC |
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) |
| 90-280 VAC (For Home Appliances) |
| Frequency Range | 50 Hz/60 Hz (Auto sensing) |
| OUTPUT | Voltage | 230VAC ± 5%(Bat Mode) |
| Surge Power | 2 times Rated power for 5 seconds |
| Overload Protection | 5s@≥150% load; 10s@110%~150% load |
| Efficiency,PV to INV. | 97% (Peak) |
| Efficiency,Battery to INV. | 94%(Peak) |
| Transfer Time | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
| Battery type | AGM/Flooded/user defined , Lithium ( need to mention when needed ) |
| BATTERY & AC CHARGER | Battery Voltage | 24 VDC | 24 VDC | 24 VDC | 48 VDC | 48 VDC | 48 VDC |
| Floating Charge Voltage | 27 VDC | 27 VDC | 27 VDC | 54 VDC | 54 VDC | 54 VDC |
| Overcharge Protection | 33 VDC | 33 VDC | 33 VDC | 63 VDC | 63 VDC | 63 VDC |
| Charge Current (Max) | 60A | 80 A | 80A | 80 A | 80A | 80 A |
| SOLAR CHARGER | PV Array Power (Max) | 2000W | 4000W | 5KW | 5000W | 6KW | 5000W |
| MPPT Range | 120 ~ 450 VDC |
| PV Array VOC (Max) | 500 VDC |
| Charging Current (Max) | 80A, AC+Solar adjustable | 80A, AC+Solar adjustable | Max100A AC+Solar | 80A, AC+Solar adjustable | Max100A AC+Solar | 80A, AC+Solar adjustable |
| Efficiency (Max) | 0.98 |
| Display | LED | Line Mode or bat Mode, Charging status ,Fault |
| LCD | Vac HZ, Charge Amp W, PV VDC Amp W , Load % VA W Amp ,bat % VDC ,,setup , Fault code, working mode, |
| Setup/Adjust parameter | Solar power /utility power/Battery priority, united Charge Current , AC Charge Amp, AC input range, VAC HZ, Bat VDC back to utility power, BAT VDC back to Bat Mode, Charge Source select ,Alarm on off , overload bypass, Bulk/ Floating Charge VDC, Bat Low Cut VDC , equalization Charge VDC / mins / days, |
| Output working Mode | utility power priority | default. Utility power priority, Solar and battery as backup when utility power not available |
| Solar priority(SUB Mode) | solar power priority, utility power supplement to load when solar power is not enough , utility not available, battery supplement to load. Working on daytime while No Bat |
| SBU priority | Solar power priority, When Solar power is not enough,battery to supplement.when battery power is not enough , utility power to load. Working on daytime while No Bat |
| Product size | L*W*H | 448*295*105mm |
| Net Weight (kgs) | Kg | 8.5 | 9 | 9 | 10 | 10 | 10 |
| Carton size | L*W*H | 590*390*208mm |
| Carton weight | Kg | 11 | 11 | 11 | 11.8 | 11.8 | 11.8 |