| Model | R5-3K-S2 | R5-4K-S2 | R5-5K-S2 | R5-6K-S2 | R5-7K-S2 | R5-8K-S2 |
| Input(DC) | ||||||
| Max.PV Array Power [Wp]@STC | 4500 | 6000 | 7500 | 9000 | 10500 | 12000 |
| Max. DC Voltage [V] | 600 | |||||
| MPPT Voltage Range [V] | 90-550 | |||||
| Nominal DC Voltage[V] | 360 | |||||
| Start Voltage [V] | 100 | |||||
| Min. DC Voltage [V] | 80 | |||||
| Max. DC Input Current [A] | 12.5/12.5 | 25/12.5 | ||||
| Number of DC Connection Sets per MPPT | 1/1 | 2/1 | ||||
| Number of MPPT | 2 | |||||
| DC Switch | Integrated | |||||
| Output (AC) | ||||||
| Rated AC Power [W] | 3000 | 4000 | 5000*1 | 6000 | 7000 | 8000 |
| Max. AC Power*1[VA] | 3300 | 4400 | 5500 | 6000 | 7700 | 8000 |
| Rated AC Current [A]@230Vac | 13.1 | 17.4 | 21.8*1 | 26.1 | 30.5 | 34.8 |
| Max. AC Current [A] | 14.4 | 19.2 | 24 | 26.1 | 33.5 | 34.8 |
| Nominal AC Voltage/ Range [V] | 220,230,240/180-280 | |||||
| Grid Frequency/ Range [Hz] | 50,60/45-55,55-65 | |||||
| Power Factor [cos φ] | 0.8 leading~0.8 lagging | |||||
| Total Harmonic Distortion [THDi] | < 2%(at nominal power) | |||||
| Feed-in | L+N+PE | |||||
| Efficiency | ||||||
| Max. Efficiency | 97.8% | 98.0% | 98.1% | 98.2% | 98.2% | 98.3% |
| Euro Efficiency | 97.2% | 97.5% | 97.6% | 97.6% | 97.7% | 97.8% |
| MPPT Accuracy | >99.9% | |||||
| Protection | ||||||
| Internal Over-voltage Protection | Integrated | |||||
| DC Insulation Monitoring | Integrated | |||||
| DC Surge Protection | Integrated | |||||
| Grid Monitoring | Integrated | |||||
| AC Short Circuit Current Protection | Integrated | |||||
| AC Grounding Detection | Integrated | |||||
| GFCI Monitoring | Integrated | |||||
| DCI Monitoring | Integrated | |||||
| AC Surge Protection | Integrated | |||||
| Thermal Protection | Integrated | |||||
| Anti-island protection monitoring | AFD | |||||
| Interface | ||||||
| DC Connection | MC4 | |||||
| AC Connection | Plug-in connector | Terminal Block | ||||
| Human Machine Interface | LED+(bluetooth/Wi-Fi+APP) | |||||
| Communication Port | RS232(USB joints)+RS485(RJ45 crystal joints) | |||||
| Communication Mode | Wi-Fi/GPRS/4G(Optional) | |||||
| General Data | ||||||
| Topology | Transformerless | |||||
| Consumption at Night [W] | <0.2 | |||||
| Consumption at Standby [W] | 6 | |||||
| Operating Temperature Range | -40°C to +60°C (running in reduced load condition when the temperature is above 45°C) | |||||
| Cooling Method | Natural Convection | |||||
| Ambient Humidity | 0-100% Non-condensing | |||||
| Altitude | 4000m(>3000m power derating) | |||||
| Noise [dBA] | <25 | |||||
| Ingress Protection | IP65 | |||||
| Mounting | Rear Panel | |||||
| Dimensions [H*W*D][mm] | 389*367*143 | 429*418*177 | ||||
| Weight [kg] | 12.2 | 18 | ||||
| Standard Warranty [Year] | 5 (standard)/10/15/20/25 (Optional) | |||||
| Applicable Standard | IEC62109-1/2,IEC61000-6-1/2/3/4,EN50438,C10/C11,IEC62116,IEC61727,RD1699,UNE 206006, UNE 206007,CEI 0-21,AS4777.2,NBR 16149, NBR 16150,VDE-AR-N 4105 | |||||
| Remarks: *1 According to VDE - ARN - N 4105, Rated AC Power for R5-5K-S2 is 4600VA; According to AS4777, Rated AC Power for R5-5K-S2 is 4999VA. *2 According to C10/C11, Max. AC Power = Rated AC Power *3 According to VDE - ARN - N 4105, Rated AC Current for R5-5K-S2 is 20A; According to AS4777, Rated AC Current for R5-5K-S2 is 21.7A. | ||||||