380 VAC 50Hz 3 Phase Power Supply Online Double-Conversion UPS with Isolation Transformer for Hospital ICU

Model NO.
LS33 Series 10K - 200Kva
Output Capacity
Large Type
Brand
Upsen or OEM
Input Voltage
3 X 380VAC/400VAC (3pH + N)
Display
LED/LCD Display
Transfer Time
Zero
Frequency
50/60Hz
Output Power Factor
0.8
Output Wave
Pure Sine Wave
Capacity
10kVA-200kVA
Transport Package
Carton/Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
5, 000PCS/Month
Reference Price
$ 900.00 - 4,500.00

Product Description

380Vac 50Hz 3 Phase Power Supply Online double-conversion UPS with Isolation transformer for Hospital ICU

Key Features
1.Online double-conversion.
2.DSP technology guarantees high reliability.
3.True galvanic isolation transformer design.
4.Control designed to withstand all kinds of loads.
5.Intelligent battery management to prolong battery lifecycle.
6.Redundant fan design and independent ventilation enhance durable operation under harsh environment.
7.Adjustable battery numbers.
8.Accept dual-mains input.
9.Parallel operation with up to 4 units (option).
10.Variety of communication options available.

Application
Data center, Industrial equipment, Financial and Securities, Large Data rooms, Postal and Telecommunications, Energy and Electricity, Industrial and Commercial tax affair,Medical and Health.

Technical Specification
LS33 Series 10K - 200Kva
MODELLS33 10KLS33 20KLS33 30KLS33  40KLS33 60KLS33 80KLS33 100KLS33 120KLS33 160KLS33  200K
CAPACITY10KVA /8KW20KVA /16KW30KVA /24KW40KVA /32KW60KVA /48KW80KVA /64KW100KVA /80KW120KVA /96KW160KVA /128KW200KVA /160KW
INPUT
Nominal Voltage3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range305VAC ~ 460VAC
Frequency46-54Hz or 56-64Hz
INVERTER
Nominal Voltage3 * 380VAC/400VAC (3Ph + N)
PrecisionStationary: ±1%
Transitory: ±5% (load variations 100-0-100%)
Frequency50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed±1 Hz/s
WaveformPure Sinewave
Total Harmonic Distortion (THDv)<2% (Linear Load)
<5% (Non-linear Load)
Phase Displacement120o ±1% (balanced load)
120o ±2% (imbalances 50% of the load)
Dynamic Recovery Time1 cycle at 98 % of the static value
Admissible Overload110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor3:1
Admissible Power Factor0.6~1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load<1%
Current LimitHigh overload, short-circuit: RMS Voltage Limit
High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
TypeSolid state
Voltage3 x 380VAC/400VAC (3Ph + N)
Frequency50/60 Hz
Activation CriterionMicroprocessor control
Transfer TimeZero
Admissible Overload150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to BypassImmediate, for overloads above 160%
RetransferAutomatic after alarm clear
MAINTENANCE BYPASS
TypeWithout interruption
Voltage3 * 400V (3Ph + N)
Frequency50/60 Hz
Overall EfficiencyLine Mode90%91%92%93%
Battery Mode90%91%93%93%
BATTERY & CHARGER
Battery Type and Numbers12VDC* 16 pcs12VDC * 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage192 VDC384 VDC (Based on 32pcs batteries)
Charging MethodCC/CV
Precision±1%
Charging CurrentMax.: 40 A
Charging Voltage216 VDC432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D*W*H(mm)656*405* 817656*405* 941840*432*1140975 *554 *12861200 *910 *16801500 *1140 *1800
Net Weight (Kgs)1802052953304515199501350
* Product specifications are subject to change without further notice
380 VAC 50Hz 3 Phase Power Supply Online Double-Conversion UPS with Isolation Transformer for Hospital ICU
380 VAC 50Hz 3 Phase Power Supply Online Double-Conversion UPS with Isolation Transformer for Hospital ICU